Changes to Step #7

Edit by Grégoire Saunier

Edit approved by Grégoire Saunier

Before
After
Unchanged

Step Lines

[title] Preparing a cable to test thermal runaway
[* icon_note] To test runaway protection (or MAXTEMP protection) you need to shortcut the thermistor pins on the Rambo board.
[* violet] You will need a Female to Female Dupon cable to shortcut the thermistor connector.
-[* black] Alternatively you can cut an old thermistor and connect both wires together (those that are connected on the connector side).
+[* black] Alternatively you can cut an old thermistor and connect both wires together (the wires that are on the connector side).
[* green] Here is an example on how to connect the Dupon cable for the next steps. Note the position is only for the example.