Skip to main content

Changes to Step #9

Edit by 3D_Gussner

Edit approved by Grégoire Saunier

Before
After
Unchanged

Step Lines

[title] Thermal Runaway Error for Hotend (2/2)
[* 1] Plug both side of your Dupon cable into the ***hotend thermistor connector*** on the controller board.
[* 1] The printer must instantly emit noisy bip.
[* 2] The ***Err: MAXTEMP*** error message should be displayed on the printer.
-[* 5] The displayed hotend temperature should show a very high value. (See example picture ***739***/0°)
-[* 1] Unplug the Dupon test cable and plug back the hotend thermistor. Make sure that the displayed hotend temperature is back to a normal value.
+[* 5] The displayed hotend temperature should show a very high value. (See example picture: ***739***/0°)
+[* 1] Unplug the Dupon test cable and plug back the ***hotend thermistor***. Make sure that the displayed hotend temperature is back to a normal value.
[* 9] If this step behaves differently please verify your connection and firmware. If it continues stop using your printer and contact us or ask for help.