[title] Thermal Runaway Error for Hotend (2/2)
[* 1] Plug both side of your Dupon cable into the ***hotend thermistor connector*** on the controller board.
-[* 1] Turn on the printer.
+[* 1] Turn the printer on.
[* 1] The printer must instantly emit noisy bip just after having started.
[* 2] The ***Err: MAXTEMP*** error message should be displayed on the printer.
[* 6] The displayed hotend temperature should show a very high value. (See example picture: ***739***/0°)
[* 1] Unplug the Dupon test cable and plug back the ***hotend thermistor***. Make sure that the displayed hotend temperature is back to a normal value.
[* 1] Turn off the printer.
[* 9] If this step behaves differently please verify your connection and firmware. If it continues stop using your printer and contact us or ask for help.