[title] Thermal Runaway Error for Heated Bed (2/2) | |
[* 1] Plug both sides of you Dupon cable into the ***heated bed thermistor connector*** on the controller board. | |
[* 2] The ***Err: MAXTEMP BED*** error message must be displayed on the printer. | |
- | [* |
+ | [* 3] The displayed heated bed temperature should show a very high value. (See example picture: ***368***/0°) |
[* 1] Unplug the Dupon test cable and plug back the ***heated bed thermistor***.Make sure that the displayed bed temperature is back to a normal value. | |
[* 1] Turn off the printer. | |
[* 9] If this step behaves differently please verify your connection and firmware. If it continues stop using your printer and contact us or ask for help. |