Changes to Step #15

Edit by 3D_Gussner

Edit approved by Grégoire Saunier

Before
After
Unchanged

Step Lines

[title] Preheat Error for Heated Bed (2/2)
-[* 1] Once the heated bed temperature is bigger than 50°C, unplug the heated bed heater from the Rambo board.
-[* 2] After few minutes and you must have the ***BED THERMAL RUNAWAY*** message displayed.
-[* 6] The targeted temperatures must be set to ***0°C***.
+[* 1] Once the heated bed temperature is higher than 40°C, unplug the ***heated bed heater*** from the controller board.
+[* 2] After few minutes and you should get the ***BED THERMAL RUNAWAY*** message displayed on the printer.
+[* 6] Set targeted temperatures back to ***0°C*** via ''Preheat/Cooldown'' or ''Settings/Temperature'' menu.
[* 1] Plug back the bed heater.
[* 1] Turn the printer off.
[* 9] If this step behaves differently please verify your connection and firmware. If it continues stop using your printer and contact us or ask for help.