[title] Filament sensor assembly
-[* 9] Verify that the ''filament_sensor_lever'' and the filament sensor pocket on top of the ''extruder_body'' does not have strings and are well printed. Clean up if necessary.
+[* 9] Verify that the ''filament_sensor_lever'' and the filament sensor pocket on top of the ''extruder_body'' do not have any strings and are printed well. Clean up if necessary.
[* 3] Insert the longer magnet (20x6x2mm) inside the ''filament_sensor_lever''.
-[* 6] Place the smaller magnet (10x6x2mm) so that it is attracted to the ''filament_sensor_lever''. The smaller magnet should be on the flat side of the lever.
-[* 4] Remove the smaller magnet from the ''filament_sensor_lever'', taking care to keep the orientation the same. Insert the smaller magnet with the same orientation into the ''extruder_body''. ***DO NOT*** insert the ''filament_sensor_lever'' yet.
-[* 9] Verify that the smaller magnet is fully pressed into its cavity.
+[* 6] Place the smaller magnet (10x6x2mm) so it is attracted to the ''filament_sensor_lever''. The smaller magnet should be on the flat side of the lever.
+[* 4] Remove the smaller magnet from the ''filament_sensor_lever'' and insert it with the same orientation into the ''extruder_body''. ***DO NOT*** insert the ''filament_sensor_lever'' yet.
+[* 9] Verify that the smaller magnet is fully inserted into its cavity.