[title] PINDA probe assembly | |
[* 4] Place a square nut in the ''extruder_body'' for the ''pinda_mount''. | |
[* 8] Slide a M3x10 screw into the ''pinda_mount'' and engage the square nut, but do not tighten yet. | |
[* 5] Insert the PINDA into the mount so that the sensor end is approximately 12mm below the bottom of the ''pinda_mount''. Tighten the screw just enough to keep the PINDA from falling out. The optimum PINDA position will be adjusted later. | |
[* 2] Route the PINDA wires as indicated | |
[* 7] Route the print fan wires as indicated | |
[* 3] Secure the wires with a zip tie. Be sure to leave some slack since the PINDA position will need to be adjusted later. | |
- | [* 6] This is the |
+ | [* 6] This is the preferred example of how the PINDA and print fan cables should be wired. |