Skip to main content

Step Type:

Drag to rearrange

Let the extruder cool down.

Place a sheet of paper on the heated bed. Manually lower the X axis until the Hemera nozzle is touching the paper.

Make sure the X axis is flat (you can slowly move the Hemera left and right while looking at the nozzle distance from the bed).

Loosen the PINDA locking screw and place an object of 1mm thickness under the Pinda (like the middle section of a zip tie).

Gently move the PINDA down until it is touching the zip tie.

Tighten the PINDA locking screw to secure it in place.

Use a plier if it is hard to reach the probe with your fingers during adjustment.