    • Let the extruder cool down.

    • Place a sheet of paper on the heated bed. Manually lower the X axis until the Hemera nozzle is touching the paper.

    • Make sure the X axis is flat (you can slowly move the Hemera left and right).

    • Loosen the PINDA locking screw and place an object of 1mm thickness under the Pinda (like the middle section of a zip tie).

    • Gently move the PINDA down until it is touching the zip tie.

    • Tighten the PINDA locking screw to secure it in place.

    • Use a plier if it is hard to reach the probe with your fingers during adjustment.